p
-
RO Series
-
Cooling water Series
-
Reagents for waste water treatment
-
Reagents for boilers
-
Reagents for oilfield
-
Reagents for central air conditioner
-
Reagents for desulfurization water
-
Reagents for nanofiltration
-
Reagents for ultrafiltration
-
Reagents for solid waste
-
Filter accessories
Product
-
C
- Shandong Shuichangqing Environmental Protection Technology Co., Ltd
- Con:Mr. Liu
- Tel:+86136-4646-5456
- Tel:+86156-6247-2567
- Add:North Luoluo Front Street, Gucheng Street, Shouguang City, Shandong Province, and East Jinhai North Road
Contact Us
1. Product Description
Alkaline Formulation,high pH liquid formula designed to remove organic, biofilm and particulate contaminants.
Suitable for use in aromatic polyamide reverse osmosis, nanofiltration (NF) and ultrafiltration (UF) membrane systems.
Highly effective cleaning capability.
Contain surfactants and chelating agents to break down organic contaminants such as grease and proteins.
Synergistic effect on microbial contamination and mixed organic-inorganic fouling.
2.Specifications and Parameters
Appearance: colorless transparent liquid
pH value (1% aqueous solution): 8
Density (20℃): ≥1.05 g/cm³.
3.Customized service
The product can be provided with different specifications and parameters according to user requirements, customized packaging, labeling, logistics services.
4.Usage and Dosage
Cleaning process
Pre-treatment: Flush the system with RO water and replace the security filter cartridge.
Preparation: Dilute at 1-3% (2% recommended) and heat to 30-40℃.
Cycle cleaning: Cycle at the recommended flow rate of the membrane manufacturer for 30 minutes, and the heavy contamination needs to be cleaned in sections.
Compound cleaning recommendations:
Alternate with acidic cleaning agents (such as SCQ Tech F806) to improve the overall descaling effect
Biological contamination can be used in conjunction with oxidizing biocides (such as hydrogen peroxide)
5.Packaging and Storage
25kg polyethylene special plastic drums, stored indoors (25 ℃) in a cool ventilated place, storage period of 12 months.
6.Safety Protection
When operating, you should carefully read the precautions labeled on the barrel, wear the correct safety protection equipment, including rubber gloves and goggles, etc., and avoid contact with the skin, eyes, etc., and if accidentally contacted, you need to immediately use a large amount of flowing clean water to wash.
For information on the safety, transportation and emergency handling of Shuichangqing products, please refer to the MSDS.